Honeywell霍尼韦尔气体探测器氢气探头 H2传感器MIDAS-E-H2X MIDAS-S-H2X
Honeywell 霍尼韦尔Midas-E系列传感器型号:
MIDAS-E-O2X MIDASEO2X O2X: Oxygen (two year warranty)
MIDAS-E-NH3 MIDASENH3 NH3: Ammonia
MIDAS-E-ASH MIDASEASH ASH: Arsine; Germane
MIDAS-E-HCL MIDASEHCL HCL: Hydrogen chloride; others (see product page)
MIDAS-E-HFX MIDASEHFX HFX: Nitrogen triflouride; others (see product page)
MIDAS-E-BR2 MIDASEBR2 BR2: Bromine; Chlorine dioxide
MIDAS-E-CFX MIDASECFX CFX: Diflouromethane; others (see product page)
MIDAS-E-CO2 MIDASECO2 CO2: Carbon dioxide
MIDAS-E-COX MIDASECOX COX: Carbon monoxide
MIDAS-E-HAL MIDASEHAL HAL: Chlorine; Fluorine
MIDAS-E-H2X MIDASEH2X H2X: Hydrogen
MIDAS-E-HCN MIDASEHCN HCN: Hydrogen cyanide
MIDAS-E-H2S MIDASEH2S H2S: Hydrogen sulfide
MIDAS-E-LEL MIDASELEL LEL: Hydrogen; Methane
MIDAS-E-NOX MIDASENOX NOX: Nitric oxide
MIDAS-E-NO2 MIDASENO2 NO2: Nitrogen dioxide
MIDAS-E-O3X MIDASEO3X O3X: Ozone
MIDAS-E-PH3 MIDASEPH3 PH3: Phosphine
MIDAS-E-SHL MIDASESHL SHL: Silane (low level)
MIDAS-E-SHX MIDASESHX SHX: Silane; Disilane
MIDAS-E-SO2 MIDASESO2 SO2: Sulfur dioxide
MIDAS-E-TEO MIDASETEO TEO: Tetraethyl orthosilicate
MDA Scientific
Midas® Sensor Cartridge
Hydrogen ppm (H2)
MIDAS-S-H2X
MIDAS-E-H2X
Midas® sensor cartridges are intended
for use only with Honeywell Analytics’
Midas® Gas Detector System. Please
refer to the Midas® Technical Manual
for further details.
Midas® is a registered trademark of Honeywell Analytics.
As with all electrochemical sensor cells, dramatic output changes in reported concentrations can be
expected under rapidly changing environmental conditions. Please ensure sensors are located in areas not
prone to sudden changes in humidity and temperature.
Actual readings may be affected by flow rates (although Midas® automatically controls flow rate within
specified ranges) and absorption on tubing and other gas path surfaces.
All sensors are shipped pre-calibrated to traceable national standards. Dependent on actual operating
conditions and overall exposure to gases, each sensor may not require in field calibration for up to 24
months subject to any requirements to calibrate from local regulations or site practices.
Calibration and challenge gases should be from a certified and reliable source.
Cross Sensitivities
Each Midas® sensor is potentially cross sensitive to other gases and this may cause a gas reading when
exposed to other gases than those originally designated. The table below presents typical readings that
will be observed when a new sensor cartridge is exposed to the cross sensitive gas (or a mixture of gases
containing the cross sensitive species).
MDA Scientific has developed a sophisticated range of highly sensitive gas detection equipment, designed to perform in ways that define new gas detection performance levels providing total solutions to protect people, improve production efficiency and reduce costs.
The MDA Scientific range of toxic gas detection