Impact (Pro) Semi-Serviceable Multi-Gas Portable

The Impact multigas monitor is supplied complete with dry cell battery holders, 4 x AA batteries, belt clip, flow adaptor, multi-lingual quick start guide (printed) and operating instructions (on CD). In addition, the Impact Pro is supplied with integral pump and pump adapter.

 

1. Instrument (sensor cartridge and accessories MUST be ordered separately)

Order Number

Impact, certified ATEX/SAA/MDA/INMETRO/MED

2302B10008BE

Impact Pro, certified ATEX/SAA/MDA/INMETRO/MED

2302B10009BE

Impact Pro IR Ready, certified ATEX

2302B10009BER

(Ready for use with IR cartridges)

 

 

Each Impact (Pro) is supplied with multiple languages pre-programmed including English, French, German, Italian, Spanish and Dutch. Upon first start up, the USER must select their required language to proceed. This may be changed by the USER via the menu as required.

 

2. Cartridge

Each sensor cartridge is supplied pre-configured and calibrated in a sealed container including installation instructions, calibration certificate and spare pump seal. Oxygen and Flammable sensors are always supplied and up to two toxic sensors may be fit.

 

Cartridges are available in either disposable or serviceable configurations subject to gas sensors fitted.Each cartridge includes pre-configured alarm levels that vary by country. To order cartridges with country specific alarm levels change the last letter

12 Month Disposable Cartridge

 

Examples with US regional settings used in this price list.

 

2 gas, Oxygen, Flammable

2302BCD2OFXXO

3 gas, Oxygen, Flammable, Carbon Monoxide

2302BCD3OFCXO

3 gas, Oxygen, Flammable, Hydrogen Sulfide

2302BCD3OFXHO

4 gas, Oxygen, Flammable, Carbon Monoxide, Hydrogen Sulfide

2302BCD4OFCHO

 

24 Month Disposable Cartridge (only two vesion avaiable for AP region)

 

4 gas, Oxygen, Flammable, Carbon Monoxide, Hydrogen Sulfide

2302BCD42FCHE

4 gas, Oxygen, Flammable, Carbon Monoxide, Hydrogen Sulfide

2302BCD42FCHO

 

Serviceable Cartridge

 

3 gas, Oxygen, Flammable, Ammonia

2302BCS3OFAXO

3 gas, Oxygen, Flammable, Carbon Dioxide

2302BCS3OFDXO

3 gas, Oxygen, Flammable, Chlorine

2302BCS3OFXLO

4 gas, Oxygen, Flammable, Ammonia, Sulfur Dioxide

2302BCS4OFASO

4 gas, Oxygen, Flammable, Ammonia, Chlorine

2302BCS4OFALO

4 gas, Oxygen, Flammable, Carbon Monoxide, Ammonia

2302BCS4OFCAO

4 gas, Oxygen, Flammable, Carbon Monoxide, Nitrogen Dioxide

2302BCS4OFCNO

4 gas, Oxygen, Flammable, Carbon Monoxide, Sulfur Dioxide

2302BCS4OFCSO

4 gas, Oxygen, Flammable, Carbon Monoxide, Chlorine

2302BCS4OFCLO

4 gas, Oxygen, Flammable, Carbon Dioxide, Ammonia

2302BCS4OFDAO

4 gas, Oxygen, Flammable, Carbon Dioxide, Carbon Monoxide

2302BCS4OFDCO

4 gas, Oxygen, Flammable, Carbon Dioxide, Hydrogen Sulfide

2302BCS4OFDHO

4 gas, Oxygen, Flammable, Carbon Dioxide, Nitrogen Dioxide

2302BCS4OFDNO

4 gas, Oxygen, Flammable, Carbon Dioxide, Sulfur Dioxide

2302BCS4OFDSO

4 gas, Oxygen, Flammable, Carbon Dioxide, Chlorine

2302BCS4OFDLO

4 gas, Oxygen, Flammable, Hydrogen Sulfide, Ammonia

2302BCS4OFHAO

4 gas, Oxygen, Flammable, Hydrogen Sulfide, Nitrogen Dioxide

2302BCS4OFHNO

4 gas, Oxygen, Flammable, Hydrogen Sulfide, Chlorine

2302BCS4OFHLO

4 gas, Oxygen, Flammable, Nitrogen Dioxide, Chlorine

2302BCS4OFNLO

4 gas, Oxygen, Flammable, Sulfur Dioxide, Hydrogen Sulfide

2302BCS4OFSHO

 

Impact Pro Sensor Cartridge Options with Infra Red Sensors

The Impact Pro IR offers many benefits that enable the user to achieve drift-free operation and longer-term stability, when compared with catalytic bead (pellistor) or photo ionization detectors (PID).  IR sensors are immune to poisons such as silicones that can contaminate Catalytic sensor types.  IR sensors can detect hydrocarbon gas levels in the absence of oxygen (O2), which cannot be achieved with catalytic bead sensors.  Typical applications would be to measure hydrocarbon gases under nitrogen storage blankets or other inert atmospheres.  IR sensors generally enable users to achieve their application requirements with an overall lower cost of ownership

All IR sensor cartridges require a modified Impact Pro IR cartridge bay, which is designated as modification state 15. If not present, this modification must be performed by your authorized Honeywell Analytics Service Center. Failure to do this may lead to physical damage when attempting to insert the new IR sensor cartridge and will not be covered by warranty.

Any electrochemical sensors in this cartridge cannot operate accurately in oxygen deficient environments and should not be used for continuous monitoring in inert atmospheres.

Serviceable Impact Pro Sensor Cartridge with Infra Red Sensor Options

Infrared sensors for flammable gases cannot detect hydrogen (H2). If the environment is suspected of containing combustible levels of hydrogen, a cartridge that uses a standard catalytic bead sensor should be used with the Impact Pro instead.

 

The flammable (%LEL or %V/V) IR sensors are factory calibrated to respond linearly to methane (CH4). Response to other hydrocarbons is non-linear and the Impact Pro IR will not display corrected values for other hydrocarbon gases. The Impact Pro IR will generally (but not always) give a higher reading for heavy hydrocarbons than for methane.

IR % LEL sensor options

 

Examples with US regional settings used in this price list

 

2 gas, Oxygen, Methane %LEL IR

2302BCS2ORXXO

3 gas, Oxygen, Methane %LEL IR, Carbon Monoxide

2302BCS3ORCXO

3 gas, Oxygen, Methane %LEL IR, Hydrogen Sulfide

2302BCS3ORXHO

4 gas, Oxygen, Methane %LEL IR, Carbon Monoxide, Ammonia

2302BCS4ORCAO

4 gas, Oxygen, Methane %LEL IR, Carbon Monoxide, Nitrogen Dioxide

2302BCS4ORCNO

4 gas, Oxygen, Methane %LEL IR, Carbon Monoxide, Sulfur Dioxide

2302BCS4ORCSO

4 gas, Oxygen, Methane %LEL IR, Carbon Monoxide, Hydrogen Sulfide

2302BCS4ORCHO

4 gas, Oxygen, Methane %LEL IR, Carbon Dioxide, Carbon Monoxide

2302BCS4ORDCO

4 gas, Oxygen, Methane %LEL IR, Carbon Dioxide, Hydrogen Sulfide

2302BCS4ORDHO

4 gas, Oxygen, Methane %LEL IR, Hydrogen Sulfide, Ammonia

2302BCS4ORHAO

4 gas, Oxygen, Methane %LEL IR, Sulfur Dioxide, Hydrogen Sulfide

2302BCS4ORSHO

 

IR % Vol Sensor Options

 

2 gas, Oxygen, Methane %Vol IR

2302BCS2OVXXO

3 gas, Oxygen, Methane %Vol IR, Carbon Monoxide

2302BCS3OVCXO

4 gas, Oxygen, Methane %Vol IR, Ammonia, Chlorine

2302BCS4OVALO

4 gas, Oxygen, Methane %Vol IR, Carbon Monoxide, Hydrogen Sulfide

2302BCS4OVCHO

4 gas, Oxygen, Methane %Vol IR, Carbon Dioxide, Hydrogen Sulfide

2302BCS4OVDHO

 

IR CO2 sensor options

 

2 gas, Oxygen, Carbon Dioxide IR

2302BCS2OTXXO

3 gas, Oxygen, Carbon Monoxide, Carbon Dioxide IR

2302BCS3OTCXO

4 gas, Oxygen, Carbon Dioxide IR, Carbon Monoxide, Sulfur Dioxide

2302BCS4OTCSO

4 gas, Oxygen, Carbon Dioxide IR, Carbon Monoxide, Hydrogen Sulfide

2302BCS4OTCHO

4 gas, Oxygen, Carbon Dioxide IR, Hydrogen Sulfide, Ammonia

2302BCS4OTHAO

4 gas, Oxygen, Carbon Dioxide IR, Sulfur Dioxide, Hydrogen Sulfide

2302BCS4OTSHO

Service modification to original Impact Pro versions to house IR cartridge option. Includes return packaging and shipping costs. Consult service center for details of MOD state

IMPACTIRMOD

 

3. Accessories

Order Number

Datalogging kit including Base Station, PSU, PC data cable and ICU  ( X = 6 - UK, 7 - EU, 8 - US, 9 - SAA )

2302B1406

Datalogging kit including Base Station, PSU, PC data cable and ICU  ( X = 6 - UK, 7 - EU, 8 - US, 9 - SAA )

2302B1407

Datalogging kit including Base Station, PSU, PC data cable and ICU  ( X = 6 - UK, 7 - EU, 8 - US, 9 - SAA )

2302B1408

Datalogging kit including Base Station, PSU, PC data cable and ICU  ( X = 6 - UK, 7 - EU, 8 - US, 9 - SAA )

2302B1409

In-situ charging kit including Base Station, PSU, NiMH batteries  ( X = 0 - UK, 1 - EU, 2 - US, 3 - SAA )

2302B1410

In-situ charging kit including Base Station, PSU, NiMH batteries  ( X = 0 - UK, 1 - EU, 2 - US, 3 - SAA )

2302B1411

In-situ charging kit including Base Station, PSU, NiMH batteries  ( X = 0 - UK, 1 - EU, 2 - US, 3 - SAA )

2302B1412

In-situ charging kit including Base Station, PSU, NiMH batteries  ( X = 0 - UK, 1 - EU, 2 - US, 3 - SAA )

2302B1413

Base Station (excludes PSU)

P2302B0800

Base Station PC data cable (RS232)

P2302D0807

Base Station power link cable (interconnects two Base Stations. Use with 2302D0787)

2302D0821

Base Station plinth

P2302B0804

Impact Configuration Utility PC Software

2302B1421

RS232 to USB adaptor (1.8 m)

151-004-555

Offline Trickle Charger (excludes PSU and NiMH batteries)

2302B0725

Pair (2) NiMH rechargeable batteries (grey)

2302B0842

Single (1) NiMH rechargeable battery grey

2302B0317

Universal AC PSU for up to 6 Base Stations.

2302D0787

In-Vehicle Charger Adaptor (12 VDC)

2302D0815

Euro Mains PSU 230 V 50 Hz

2302D0816

UK Mains PSU 230 V 50 Hz

2302D0818

USA Mains PSU 120 V 60 Hz

2302D0819

Australian Mains PSU 240 V 50 Hz

2302D0820

Hand Aspirator Kit (includes 20 cm Tube and In-Line Filter)

2302B0813

Pump Adaptor Kit (comprises Pump Adaptor, 20 cm Tube and In-Line Filter)

P2302B0814

10 m (30ft) Sample Tube and In-Line Coupler

2302B0828

Ball Float

2302B0846

1 m (3ft) 4-Part Sampling Probe

2302B0847

Safelink Cable including 2x Cable Restraints to 10 m

2302B0735

Safelink Cable including 2 x Cable Restraints to 50 m

2302B0737

Safelink Cable including 2 x Cable Restraints to 100 m

2302B0746

Earpiece (included tubing and adaptor)

2302B0841

Belt Clip (metal)

P2302D0826

Webbing clip

P2302B0382

Body Harness Kit (includes Harness Plate and 2 straps)

P2302B0822

Field Case

2302D0722

Printed Manual (please specify language)

2302M5030

Leather Case

2302D1320

 

 

4. Calibration & Test Equipment

Order Number

Basic Enforcer (excludes multigas cylinder)

2302B0650

Enforcer (includes EN50054 multigas cylinder) UL version

2302B0831

Enforcer (includes EN61779 multigas cylinder) ATEX version

2302B1336

Enforcer calibration instructions labels pack (10) English (UL)

2302B1385

Multigas Mix in N2 (1 litre, 34 Bar) 2.5%V/V CH4, 100 ppm CO, 40 ppm H2S, 15% V/V O2

2302D0833

Multigas Mix in N2 (1 litre, 34 Bar) 2.5% V/V CH4, 100 ppm CO, 40 ppm H2S, 15% V/V O2  (12 pack)

2302N0833

Multigas Mix in N2 (1 litre, 34 Bar) 2.2% V/V CH4, 100 ppm CO, 40 ppm H2S, 15% V/V O2

2302D0761

Multigas Mix in N2 (1 litre, 34 Bar) 2.2% V/V CH4, 100 ppm CO, 40 ppm H2S, 15% V/V O2 (12 pack)

2302N0761

1.5% v/v CO2, balance air calibration gas (103 L)

2992-0030

2.5% v/v CO2, balance air calibration gas (103 L)

N600-1001-38

O2 (1 litre, 34 Bar) 17% V/V O2 in N2

2302D0750

CH4 (1 litre, 34 Bar) 2.5% V/V CH4 in Air

2302D0751

H2S (1 litre, 34 bar) 25 ppm H2S in air

2302D0752

CO (1 litre, 34 Bar) 250 ppm CO in Air

2302D0753

CO2 (1 litre, 34 Bar) 2% V/V CO2 in Air

2302D0754

NO2 (1 litre, 34 Bar) 10 ppm NO2 in Air

2302D0755

NH3 (1 litre, 34 Bar) 50 ppm NH3 in Air

2302D0756

Cl2 (1 litre, 34 bar) 5 ppm Cl2 in air (max. 6 mo shelf life)

2302D0757

SO2 (1 litre, 34 Bar) 10 ppm SO2 in Air

2302D0758

N2 (1 litre, 34 Bar) 100% V/V

2302D0760

Gas Cylinder Carrying Case

08900-A-6690

Cylinder recycling toolkit renders cylinder safe for return transport

GFV4250

Tubing PU 6 mm ID x 9 mm OD  2 m  Bagged

402-190-120

Flow Regulator 0.3 litres per minute

235-285-085

Flow Regulator 0.5 litres per minute (for Chlorine)

P071 0095 00

 

 

5. Consumables

Order Number

In-line Filter - Pack of 10

2302B0845

Cartridge Seal Kit - Pack of 10

2302B0866

Pump Seal / Filter - Pack of 10

2302B1307

Gore-Tex Grille Filter - Pack of 10

2302B1308

Sounder Seal / Filter - Pack of 10

2302B1309

'O' ring Service Kit - Pack of 10

2302B1317

Stainless Steel Grille Filter for Chlorine Instruments

P2302D0823

Replacement 20 cm tube for Hand Aspirator or Pump Adaptor

402-190-070

Replacement in-line filter for Hand Aspirator or Pump Adaptor

2302D0729

 

 

6. Spares

Order Number

Spare Sensors

 

Carbon Dioxide (SureCell) (D)

2125B1004

Oxygen (O)

2115B4530

Flammable (F)

2118B0106

Hydrogen Sulfide (H)

2119B1000

Carbon Monoxide (C)

2119B1001

Chlorine (L)

2119B1002

Methane IR sensor (% LEL) (R)

2302B1081

Methane IR sensor (% Vol) (V)

2302B1082

Carbon Dioxide IR sensor (T)

2302B1083

 

 

Instrument spares

 

Dry Cell Battery Holder - Pair

2302B0770

Pump Adaptor

2302B0809

Replacement Pump and Seal Kit

2302B1091

Pump Blank

2302B1310

Spare Cable Clip Safelink