Date:2017-10-18 Hits:3891
Fireye® provides a variety of flame safeguard and combustion controls to the HVAC market place. Our BurnerLogix®, Flame Monitor® and MicroM® families provide safe and reliable light off of packaged burners used on commercial and industrial boilers as well as direct fired make up air units and commercial hot water heaters. Anywhere you are trying to safely control a flame, you will find a Fireye control.
BurnerLogix® Burner Management Control System
With the introduction of the new Adaptive Infrared (IR) Amplifier technology, the BurnerLogix becomes one with the burner, no matter which fuel is being burned.Built in techniques and algorithms allow the BurnerLogix to learn the characteristics of the fuel being burned and set its internal thresholds to optimize detection under all conditions. And when firing conditions change for the worse, the Adaptive IR system reacts properly and safely shuts the burner down.The BurnerLogix has a smaller footprint than previous offerings, almost 50% less. With the keypad selectable parameters, most applications requirements are easily solved with one programmer module, resulting in fewer spare parts.New features like ‘revert to pilot’ can increase a burner’s turndown capability. The new pigtail wiring base can save time and labor at the OEM’s and can make upgrading existing installations easy and quick.For a low cost solution to efficiency gains, check out our BurnerLogix Z Control. With integrated flame safeguard and boiler control operaton, the Z model provides simplified operation for single point applications.
BURNERLOGIX® Y FLAME SAFEGUARD CONTROL
BurnerLogix Y (YB110) Primary Safety Controls provide full function to basic control for all your application needs. BurnerLogix is a small and compact package filled with big features and huge benefits.
For the past 20 years, from the introduction through the
continuous improvement of the Flame-Monitor system,
Fireye has continually set new standards in the development
of burner controls. With the use of microprocessors,
Fireye has brought a new level of intelligence into the
operation of a burner. Controls have become smarter,
more accurate, and more reliable resulting in more
dependable operation. Using digital signal processing techniques,
the operation of a burner with a Fireye
Flame-Monitor control is now less dependent on environmental
conditions that can lead to wide and undesirable
operating margins.
The Flame-Monitor is the benchmark by which all other
burner controls are measured.
then Perfection is BurnerLogix™
• Smaller footprint saves space
• Bright vacuum fluorescent display
• SMART LED’s for status and diagnostics
• Keypad configurable parameters
• Expanded keypad functions
• Built-in language selection
• Plug-in programmer modules
• Expanded programmer functions
• Pigtail pre-wired wiring base available
• Din rail mount
• Enhanced communications
• International approvals
A Burner’s Favorite Control
BurnerLogix Primary Safety Controls provide full function to basic control for all your application needs.
BurnerLogix is a small and compact package filled with big features and huge benefits.
BurnerLogix™ Features Include:
• Keypad configured parameters
• Bright Vacuum Fluorescent Display
• NEM4 display mounting
• SMART LED’s – provides status and lockout codes
• Keypad selectable languages
• Smaller size than E110
• Din rail mounting
• Pigtail or terminal block style wiring base
• Automatic 8 hour burn-in based on burner on time
• Valve proof of closure during standby and startup
• Enhanced communications, Adjustable baud rates
• 4-20 mA test jack signal
• Additional inputs and outputs
BurnerLogix™ Benefits Include:
• Fewer programmer modules to inventory
• Variable parameters help resolve all applications
• Reduced downtime, pinpoint diagnostics
• Cabinet mounting space reduced by 40% to 50%
• Wires pre-marked for ease of installation
• Added safety during idle or off periods
• Easily adapts into most building management systems
• Improved turndown control from Plant Master
Differentiators
1. Size – footprint reduced to 20 in2 from 40 in2
with pigtail wiring base
2. Size – footprint reduced to 28 in2 from 40 in2
with terminal block wiring base
3. Display – LCD, expanded cold temperature to
-25° C
4. Display – VFD, increased brightness, operates
to -40° C
5. Expanded keypad – forward and reverse keys
simplifies parameter selection
6. Pre-wired base – ease of installation, no wires
to cut
7. Smart LED’s – provides status and lockout
codes
8. 4-20 mA test jack signal
9. Keypad configurable parameters – reduced
inventory
10. 8 hour burn-in based on burner on time – less
chance of mistake
11. Proof of closure during standby
12. Terminal block wiring base – allows testing with
control installed
13. Able to provide YP138 function
14. Additional inputs
15. Additional output for secondary valve,
ignitor, etc
16. Adjustable baud rates for modbus
communications
BurnerLogix™ Features Include:
• Keypad configured parameters
• Bright Vacuum Fluorescent Display
• NEM4 display mounting
• SMART LED’s – provides status and lockout codes
• Keypad selectable languages
• Smaller size than E110
• Din rail mounting
• Pigtail or terminal block style wiring base
• Automatic 8 hour burn-in based on burner on time
• Valve proof of closure during standby and startup
• Enhanced communications, Adjustable baud rates
• 4-20 mA test jack signal
BurnerLogix™ Benefits Include:
• Fewer programmer modules to inventory
• Variable parameters help resolve all applications
• Reduced downtime, pinpoint diagnostics
• Cabinet mounting space reduced by 40% to 50%
• Wires pre-marked for ease of installation
• Added safety during idle or off periods
• Easily adapts into most building management systems
• Improved turndown control from Plant Master
BURNERLOGIX System Components
CHASSIS/AMPLIFIER
120 VAC, 50/60 Hz
YB110UV
YB110UVSC
YB110IR
YB110FR
YB110DC
YP100
YP102
YP200
YP202
YP300
YP302
YP113
YP138
DISPLAY MODULE
BLV512 - VACUUM FLUORESCENT
BLL510 - LIQUID CRYSTA
WIRING BASE
60-2814-1
OPEN BOTTOM
CABINET MOUNT
60-2812-1
CLOSED BOTTOM
CONDUIT KNOCKOUT
WIRING BASE
60-2810-1
PRE-WIRED
4 FOOT
COLOR CODED
Think BurnerLogix from Fireye!
With the introduction of the new Adaptive Infrared (IR) Amplifier
technology, the BurnerLogix becomes one with the burner, no matter
which fuel is being burned.
Built in techniques and algorithms allow the BurnerLogix to learn the
characteristics of the fuel being burned and set its internal thresholds
to optimize detection under all conditions. And when firing conditions
change for the worse, the Adaptive IR system reacts properly and safely
shuts the burner down.
The BurnerLogix has a smaller footprint than previous offerings, almost
50% less. With the keypad selectable parameters, most applications
requirements are easily solved with one programmer module, resulting
in less inventory of spare parts.
New features like ‘revert to pilot’ can increase a burner’s turndown
capability. The new pigtail wiring base can save time and labor at the
OEM’s and can make upgrading existing installations easy and quick.
BurnerLogixTM Bulletins
Pub No.
Product
Pub No.
Product
133-675 BurnerLogiX Installation Instructions for 129-178 Remote Display Mounting Kits 133-676 BurnerLogiX Installation Instructions for PigTail Wiring Base for Y type only, 60-2810-1, 60-2812-1, 60-2814-1
133-677 BurnerLogiX Installation Instructions for Terminal Block Wiring Base w/Knockoutsfor Y type only 133-701 BurnerLogiX Installation Instructions for PigTail Wiring Base for Z type only, 60-2850-1,
133-702 BurnerLogix Installation Instructions for terminal block wiring base for Z type only, 60-2852-1, 60-2854-1 133-707 Terminal Block Wiring Base Used with BurnerLogix YZ300 Interlock Annunciator
133-722 Errata Sheet for 61-7161 PowerFlame BLZ-SET BurnerLogix Z Programming/Set-Up Guide
BD-5001 BurnerLogiX Installation Instructions for Displays, BLV512, BLL510 BL-1001 BurnerLogiX Y Modules & Displays, YB110UV, YB110UVSC, YB110IR, YB230UV, YB230UVSC, YB230IR
BLZ-1001 Microprocessor-Based Burner Management Control with Integrated Boiler Control Operation, ZB110UV, ZB110UVSC, ZB110IR BLZPTS-1 Pressure & Temperature Sensors for BurnerLogiX, TS350, TS752, BLPS
YBT-1000 Test Unit for BurnerLogix™ Y Controls, 57YB4-5000 YP-1001 BurnerLogiX YP Programmers, YP100, YP102, YP113, YP138, YP200, YP202, YP300, YP302
YZEM-3001 Interlock Annunciator for use with the Fireye BurnerLogix™ Control, YZ300, 60-2872-1, 60-2874-1 YB110-Spec BurnerLogix Y Product Specification Guide
YZ300P YZ300P windows based software for programming custom messages into the YZ300 BurnerLogix Interlock Annunciator (self extracting zip file) YZ300-Spec Interlock Annunciator for use with BurnerLogix Controls
UC-4851 UC485 Optically isolated USB to RS422/RS485 converter ZB110-Spec BurnerLogix Z Product Specification Guide
133-691 Using Noise Reduction Kit 129-179