Honeywell Gas Detector About:

Midas gas detector | Sensepoint XCD | FSX Flame Detector | FS10-R FSX Flame Detectors | FS24X Flame Detector | Fire Sentry FS20X | Impulse portable gas detector | Satellite XT | SS4/SS2 Flame Detector | FS7 Flame Detector | HONEYWELL ANALYTICS PORTABLES |


Honeywell Gas Detector

Date:2017-10-19     Hits:2849

Series 3000 Mkll and Mklll Transmitters with Sensor
Intrinsically Safe Transmitters

2-wire loop powered toxic and Oxygen gas detector for use in potentially explosive atmospheres - explosion proof and intrinsically safe versions
Features & Benefits
Reliable detection
Reduced installation costs
Reduced commissioning costs
Quick Specs
Maximum dimensions 164mm x 201mm x 99mm (6.4” x 7.9” x 3.9”)
Operating humidity continuous 20-90% RH (non-condensing) 

Operating pressure 90-110kPa


Product Overview


The Series 3000 range of transmitters provide comprehensive monitoring of toxic and Oxygen gas hazards in potentially explosive atmospheres. Suitable for mounting both indoors and out, they are available in two versions and offer excellent versatility. The MkII is contained in a flameproof housing, has an intrinsically safe sensor connection and is for use in predominantly Zone 1 applications. However with the use of the optional remote mounting kit the sensor of the MkII can be mounted in a Zone 0 environment. The MkIII is for use with a separate suitable IS barrier allowing the complete transmitter to be used in Zone 0 applications.

These low powered gas detectors all feature a loop powered 4-20 mA connection, making them ideal for both new and retrofit installations. Users can configure the detector through the use of the easy to read LCD and intuitive interface while fault diagnostic software and a programmable calibration period greatly simplify maintenance procedures.

Accessories

Series 3000 Mkll and Mklll Calibration Cup
S3KCAL


Series 3000 Mkll and Mklll Duct Mounting Kit
S3KDMK
Series 3000 Mkll and Mklll Duct Mounting Kit


Series 3000 Mkll and Mklll Remote Mounting Kit
S3KRMK
Series 3000 Mkll and Mklll Remote Mounting Kit


Series 3000 MkII
and MkIII

The Series 3000 range of transmitters provide
comprehensive monitoring of toxic and Oxygen gas
hazards in potentially explosive atmospheres. Suitable
for mounting both indoors and out, they are available in
two versions and offer excellent versatility. The MkII is
contained in a flameproof housing, has an intrinsically safe
sensor connection and is for use in predominantly Zone 1
applications. However with the use of the optional remote
mounting kit the sensor of the MkII can be mounted in a
Zone 0 environment. The MkIII is for use with a separate
suitable IS barrier allowing the complete transmitter to be
used in Zone 0 applications.
These low powered gas detectors all feature a loop
powered 4-20 mA connection, making them ideal for
both new and retrofit installations. Users can configure
the detector through the use of the easy to read LCD
and intuitive interface while fault diagnostic software
and a programmable calibration period greatly simplify
maintenance procedures.


Reliable detection
• Proven electrochemical
sensing technology
• Uses Surecell™ electrochemical cells,
ideal for hot and humid environments
• Long-life sensing elements
• Patented ‘Reflex’ sensing element
verification diagnostics
Reduced installation costs
• Integral surface mounting lugs
• Optional horizontal or vertical pipe
mounting bracket
• Flameproof transmitter allows field
wiring to be run along with other
non-IS instruments
• Plug-in sensor removes wiring
• Can be retrofitted in place of Series 2000
Reduced commissioning costs
• Sensor recognition feature auto
configures transmitter
• Non-intrusive configuration
• Plug and play factory configured sensors
Reduced maintenance costs
• IS sensor connection permits hot swap,
reducing downtime
• User programmable calibration
frequency
• Integral fault diagnostic software
• Menu/icon driven calibration
procedure
Regulatory compliance
• European (ATEX)
• US (UL)
• Canadian (c-UL)
• South America (Inmetro)
• International (IECEx)
Range of optional accessories
• Remote sensor mounting kit
• Duct mounting kit (for H2, CO
and H2S only)
• Calibration cup to apply test gas
• Collecting cone
Typical applications
• Exploration and drilling platform
• Production platforms
• Onshore oil and gas terminals
• Refineries and chemical plants
• Power plants
• Waste water facilities
• Utilities 

Series 3000 MkII and MkIII Detector
Use Rugged and reliable gas detector for the protection of personnel from toxic and Oxygen gas hazards. MkII version
suitable for use in Zone 1, 2, 21 or 22 hazardous areas and North American Class I and II Division 1 or 2 areas.
MkIII version suitable for use in Zone 0, 1, 2, 20, 21 or 22 applications.
Detectable Gases
Technical Summary
Construction
Material Transmitter: Epoxy painted aluminium alloy LM25 or 316 Stainless Steel, Sensor: 316 Stainless Steel with PTFE filter
Maximum Dimensions 164mm x 201mm x 99mm (6.4” x 7.9” x 3.9”)
Weight Aluminium alloy LM25: 1.7kg (3.75lbs.) Stainless Steel 316: 3.7kg (8.16lbs.)
Environmental
IP Rating IP66 (EN 60529), NEMA 4X
Certified Temperature ATEX/IECEX: -20°C to +55°C (-4°F to +131°F) (MkIII -40°C to +55°C (-40°F to +131°F))
UL/c-UL: -40°C to +55°C (-40°F to +131°F)
Operating Humidity Continuous 20-90% RH (non-condensing) Intermittent 0-99% RH (non-condensing)
Operating Pressure 90-110kPa
Storage Conditions 15°C to 30°C (59°F to 86°F), 30-70% RH (non-condensing)
Electrical

Connections and Power MkII MkIII
2-wire loop powered
17Vdc (±10%) to 32Vdc (max)
22mA max. over range
2 wire loop powered
10Vdc (±10%) to 30Vdc (max)
22mA max. overrange
Entity parameters for Barrier Selection:
Vmax/Ui = 30Vdc
Imax/Ii = 125mA
Pmax/Pi = 1.2W
Li = 0mH
Ci = 0µF
Recommended Cable 2-wire with screen (90% coverage) or conduit
0.5mm2
 (20AWG) to 2.0mm2
 (14AWG)
Signal 0-100% FSD 4-20mA
Fault = 3mA
Calibration due selectable off or 3mA
Max. over range 22mA
Inhibit (toxic sensors) = Selectable 3mA or 4mA
Inhibit (Oxygen sensors) = Selectable 3mA or 17.4mA

*Suitable for applications without NH3
ambient background concentrations only.
**When operating in Hazardous Area
applications the detector must not be
operated outside the certified temperature
range. See Certification details for UL,
c-UL and ATEX/IECEx certified temperature
ranges.
1
 +55°C / 131°F intermittent.
Gas Formula Selectable Full
Scale Range
Default Range Operating Temperature**
Min Max
Oxygen O2 25.0% / Vol only 25.0%Vol -30°C / -22°F 55°C / 131°F
Hydrogen Sulphide H2
S 10.0 to 50.0ppm 15.0ppm -40°C / -40°F 55°C / 131°F
Hydrogen Sulphide H2
S 50 to 500ppm 100ppm -40°C / -40°F 55°C / 131°F
Carbon Monoxide CO 100 to 500ppm 300ppm -40°C / -40°F 55°C / 131°F
Sulphur Dioxide SO2 5.0 to 20.0ppm 15.0ppm -40°C / -40°F 55°C / 131°F
Ammonia* NH3 50 to 200ppm 200ppm -20°C / -4°F 40°C / 104°F1
Ammonia* NH3 200 to 1,000ppm 1,000ppm -20°C / -4°F 40°C / 104°F
Chlorine CI2 5.0 to 20ppm 5.0ppm -10°C / 14°F 55°C / 131°F
Chlorine Dioxide CIO2 1.00ppm only 1.00ppm -20°C / -4°F 55°C / 131°F
Nitric Oxide N0 100ppm only 100ppm -20°C / -4°F 55°C / 131°F
Nitrogen Dioxide NO2 5.0 to 50.0ppm 10ppm -20°C / -4°F 55°C / 131°F
Hydrogen H2 1,000ppm only 1,000ppm -20°C / -4°F 55°C / 131°F
Hydrogen H2 9,999ppm only 9,999ppm -20°C / -4°F 55°C / 131°F
Hydrogen Chloride HCI 10.0 to 20.0ppm 10ppm -20°C / -4°F 40°C / 104°F
Hydrogen Cyanide HCN 30.0ppm only 30.0ppm -20°C / -4°F 55°C / 131°F
Hydrogen Fluoride HF 12.0ppm only 12.0ppm -20°C / -4°F 55°C / 131°F
Phosphine PH3 1.2ppm only 1.2ppm -20°C / -4°F 40°C / 104°F
Fluorine F2 4.00ppm only 4.00ppm -20°C / -4°F 55°C / 131°F
Ozone O3 0.400ppm only 0.400ppm -20°C / -4°F 55°C / 131°F
Ethylene Oxide ETO 20.0 to 50.0ppm 25.0ppm -20°C / -4°F 55°C / 131°F


Certification

MkII MkIII
Transmitter:
UL/c-UL: Class I, Div. 1 & 2, Groups B, C & D;
Class II, Div. 1 Groups E, F & G, Class II, Div. 2, Groups
F & G; Class I, Zone 1, Group IIB + H2 Hazardous
Locations
ATEX: II 2 (1) GD Ex d [ia IIC Ga] IIB + H2 T4 Gb
Ex t [ia IIIC Da] IIIB T135°C Db
IECEx: Ex d [ia IIC Ga] IIB + H2 T4 Gb Ex t [ia IIIC Da]
IIIB T135°C Db
Transmitter:
UL/cUL Class I, Divisions 1 & 2, Groups A, B, C & D;
Class II, Divisions 1 & 2, Groups E, F & G
ATEX: II 1 (1) GD Ex ia IIC T4 Ga Ex ia IIIC T135°C Da
IECEx: Ex ia IIC T4 Ga Ex ia IIIC T135°C Da
Remote Sensor Accessory:
UL/c-UL: Class I, Division 1, Groups A, B, C and D
Class II, Divisions 1 and 2, Groups E, F and G
Class 1, Zone 0, Group IIC; Class II, Zone 20
ATEX: II 1G D Ex ia IIC T4 Ga Ex ia IIIC T135°C Da
IECEx: Ex ia IIC T4 Ga Ex ia IIIC T135°C Da
Remote Sensor Accessory:
UL/c-UL = Class I, Div. 1, Groups A, B, C & D; Class II
Division 1 & 2, Groups E, F & G; Class 1, Zone 0, Group IIC;
Class II, Zone 20
ATEX: II 1G D Ex ia IIC T4 Ga Ex ia IIIC T135°C Da
IECEx: Ex ia IIC T4 Ga Ex ia IIIC T135°C Da
Approvals CE compliant in accordance with: ATEX Directive 94/9/EC, EMC Directive 2004/108/EC, EN 50270

Ordering Information
A complete assembly consists of two parts, a transmitter and sensor which must be ordered separately.
• Transmitter PN#: Two certified versions are available:
- ATEX/IECEx approved version (Aluminium version part number S3KAL2, S3KAL3 Stainless Steel version part
 number S3KAS2, S3KAS3)
- UL/CSA approved version (Aluminium version part number S3KUL2, S3KUL3, Stainless Steel version part
 number S3KUS2, S3KUS3)
- Inmetro approved version (Aluminium version part number S3KNL2, S3KNL3, Stainless Steel version part
 number S3KNS2, S3KNS3)
• Sensor PN#: All certified ATEX, IECEx, UL, CSA (c-UL) with two digits to specify gas type and range:
- e.g. S3KXXC1SS (C1 denotes Carbon Monoxide, with a default range of 0-300ppm and user configurable for
 ranges from 0-100ppm to 0-500ppm (in 100ppm steps))


Transmitter

Sensor Part Numbers and Available Gases
S3KXSO1SS Oxygen (O2
) 0-25% Vol
S3KXSC1SS Carbon Monoxide (CO) 0-300ppm (default) 0-100 to 0-500ppm selectable
S3KXSC2SS Carbon Monoxide (CO) 0-300ppm (default) 0-100 to 0-999ppm selectable
S3KXSH1SS Hydrogen Sulphide (H2
S) 0-15ppm (default) 0-10 to 0-50ppm selectable
S3KXSH2SS Hydrogen Sulphide (H2
S) 0-100ppm (default) 0-50 to 0-500ppm selectable
S3KXSL1SS Chlorine (CI2
) 0-5ppm (default) 0-5 to 0-20ppm selectable
S3KXSS1SS Sulphur Dioxide (SO2
) 0-15ppm (default) 0-5 to 0-20ppm selectable
S3KXSX1SS Chlorine Dioxide (CIO2
) 0-1ppm only


Ordering Information Continued
S3KXSM1SS Nitrogen Monoxide (NO) 0-100ppm only
S3KXSN1SS Nitrogen Dioxide (NO2
) 0-10 ppm (default) 0-5 to 0-50 ppm selectable
S3KXSG1SS Hydrogen (H2
) 0-1000ppm only
S3KXSG2SS Hydrogen (H2) 0-10,000 only
S3KXSR1SS Hydrogen Chloride (HCI) 0-10ppm (default) 0-10 to 0-20ppm selectable
S3KXSA1SS Ammonia (NH3
) 0-200ppm (default) 0-50 to 0-200ppm selectable
S3KXSA2SS Ammonia (NH3
) 0-1000ppm (default) 0-200 to 0-1,000ppm selectable
S3KXSY1SS Hydrogen Cyanide (HCN) 0-30 ppm only
S3KXSF1SS Hydrogen Fluoride 0-12 ppm only
S3KXSP1SS Phosphine 0-1.2 ppm only
S3KXSU1SS Florine (F2
) 0-4.00ppm only
S3KXSZ1SS Ozone (O3
) 0-0.400ppm only
S3KXSE1SS Ethylene Oxide (ETO) 0-25.0ppm (default) 0-20.0 to 0-50.0ppm selectable
Shipping Details
Shipping carton dimensions 315mm (12.4”) (L) x 230mm (9.0”) (W) x 115mm (4.5”) (D)
Approximate weight Aluminium alloy LM25 : 1.7kg (3.75lbs.) Stainless Steel 316 : 3.7kg (8.16lbs.)
Optional Accessories
SPXCDMTBR Pipe Mounting Bracket
SPXCDSDP Sunshade/Deluge Protection
S3KCAL Calibration gas flow housing
S3KCC Collecting cone (for use when detecting Hydrogen gas only)
S3KDMK Duct mounting kit (for use when detecting O2, CO, H2S or H2 gas)
S3KRMK ATEX/UL/c-UL approved remote sensor mounting kit (includes enclosure with sensor socket, 15m (50feet) of digital cable and glands, transmitter cable plug, mounting screws)Calibration Gases Contact Honeywell Analytics representative

1 TRANSMITTER

Series 3000 MkII transmitter (flameproof) is supplied complete with integral surface mounting lugs, 2 x 3/4"NPT or 2 x M20 conduit/cable entries (certification dependent), 1 x suitable blanking plug, 1 x hex wrench set, weatherproof cap, operating magnet, calibration & test certificate and instruction manual. Gas specific Sensor and accessories  to be ordered separately.

ATEX/IECEx Approved

 

S3KAL2

ATEX/IECEx approved Series 3000 MkII toxic and oxygen transmitter, Aluminium LM25 and 2 x M20 entries

S3KAS2

ATEX/IECEx approved Series 3000 MkII toxic and oxygen transmitter, Stainless Steel 316 and 2 x M20 entries

 

UL/c-UL Approved

S3KUL2

UL/cUL approved Series 3000 MkII toxic and oxygen transmitter, Aluminium LM25 and 2 x 3/4”NPT entries

S3KUS2

UL/cUL approved Series 3000 MkII toxic and oxygen transmitter, Stainless Steel 316 and 2 x 3/4”NPT entries

Series 3000 MkIII transmitter (Intrinsically Safe) is supplied complete with integral surface mounting lugs, 2 x 3/4"NPT or 2 x M20 conduit/cable entries (certification dependent), 1 x suitable blanking plug, 1 x hex wrench set, weatherproof cap, operating magnet, calibration & test certificate and instruction manual. Gas specific Sensor and accessories  to be ordered separately.

 

ATEX/IECEx Approved

 

S3KAL3

ATEX/IECEx approved Series 3000 MkIII toxic and oxygen transmitter, Aluminium LM25 and 2 x M20 entries

S3KAS3

ATEX/IECEx approved Series 3000 MkIII toxic and oxygen transmitter, Stainless Steel 316 and 2 x M20 entries

 

UL/c-UL Approved

S3KUL3

UL/cUL approved Series 3000 MkIII toxic and oxygen transmitter, Aluminium LM25 and 2 x 3/4”NPT entries

S3KUS3

UL/cUL approved Series 3000 MkIII toxic and oxygen transmitter, Stainless Steel 316 and 2 x 3/4”NPT entries

2. SENSOR

Serviceable Sensor (316 Stainless Steel).

 

S3KXSO1SS

Oxygen 0-25%VOL

S3KXSC1SS

Carbon Monoxide 0-300ppm default range (configurable 0-100ppm up to 0-500ppm in 100ppm increments)

S3KXSC2SS

Carbon Monoxide 0-300ppm default range (configurable 0-100ppm up to 0-999ppm in 100ppm increments)

S3KXSH1SS

Hydrogen Sulfide 0-15ppm default range (configurable 0-10ppm up to 0-50ppm in 1ppm increments)

S3KXSH2SS

Hydrogen Sulfide 0-100ppm default range (configurable 0-50ppm up to 0-500ppm in 10ppm increments)

S3KXSL1SS

Chlorine 0-5.0ppm default range (configurable 0-5.0ppm up to 0-20.0ppm in 5.0ppm increments)

S3KXSS1SS

Sulfur Dioxide 0-15.0ppm default range (configurable 0-5.0ppm up to 0-20.0ppm in 5.0ppm increments)

S3KXSX1SS

Chlorine Dioxide 0-1.00ppm

S3KXSM1SS

Nitrogen Monoxide 0-100ppm

S3KXSN1SS

Nitrogen Dioxide 0-10.0ppm default range (configurable 5.0ppm up to 0-50.0ppm in 5.0ppm increments)

S3KXSG1SS

Hydrogen 0-1000ppm

S3KXSG2SS

Hydrogen 0-10,000ppm

S3KXSR1SS

Hydrogen Chloride 0-10ppm (10.0 to 20.0ppm, 1.0ppm)

S3KXSA1SS

Ammonia 0-200ppm default range (configurable 0-50ppm up to 0-200ppm in 50ppm increments)

S3KXSA2SS

Ammonia 0-1000ppm default range (configurable 0-200ppm up to 0-1000ppm in 50ppm increments)

S3KXSF1SS

Hydrogen Fluoride 0-12.0ppm

S3KXSP1SS

Phosphine 0-1.2ppm

S3KXSY1SS

Hydrogen Cyanide 0-30.0ppm

S3KXSU1SS

Fluorine 4ppm

S3KXSE1SS

Ethylene Oxide (ETO), 25.0ppm (20.0 to 50.0ppm)

3. ACCESSORIES, CONSUMABLES & SPARES

Accessories

 

S3KCAL

Calibration cup (flow adaptor)

S3KCC

Collecting cone (for CO & H2 only)

S3KDMK

Duct mounting kit (for CO, H2 & H2S only)

S3KRMK

Remote sensor mounting kit

SPXCDMTBR

Mounting bracket (inc. bolts, nuts, brackets)

SPXCDSDP

Sunshade / Deluge Protection

SGPTPRMTL1

Single channel zener barrier MTL7728+

SGPTPRMTL2

2 channel zener barrier MTL7787+

SGPTPRMTL3

Galvanic Isolator MTL 5042

SGPTPRPFG1

Galvanic Isolator P&F KFD2-STC4-EX1

 

Consumables: Spare Cells for use with Serviceable Sensor.

 

S3KO1SS

Oxygen 0-25%VOL

S3KC1SS

Carbon Monoxide 0-300ppm default range (configurable 0-100ppm up to 0-1000ppm in 100ppm increments)

S3KH1SS

Hydrogen Sulfide 0-15ppm default range (configurable 0-10ppm up to 0-50ppm in 1ppm increments)

S3KH2SS

Hydrogen Sulfide 0-100ppm default range (configurable 0-50ppm up to 0-500ppm in 10ppm increments)

S3KL1SS

Chlorine 0-5.0ppm default range (configurable 0-5.0ppm up to 0-20.0ppm in 5.0ppm increments)

S3KS1SS

Sulfur Dioxide 0-15.0ppm default range (configurable 0-5.0ppm up to 0-20.0ppm in 5.0ppm increments)

S3KX1SS

Chlorine Dioxide 0-1.00ppm

S3KM1SS

Nitrogen Monoxide 0-100ppm

S3KN1SS

Nitrogen Dioxide 0-10.0ppm default range (configurable 5.0ppm up to 0-50.0ppm in 5.0ppm increments)

S3KG1SS

Hydrogen 0-1000ppm

S3KG2SS

Hydrogen 0-10,000ppm

S3KR1SS

Hydrogen Chloride 0-10ppm (10.0 to 20.0ppm, 1.0ppm)

S3KA1SS

Ammonia 0-200ppm default range (configurable 0-50ppm up to 0-200ppm in 50ppm increments)

S3KA2SS

Ammonia 0-1000ppm default range (configurable 0-200ppm up to 0-1000ppm in 50ppm increments)

S3KF1SS

Hydrogen Fluoride 0-12.0ppm

S3KP1SS

Phosphine 0-1.2ppm

S3KY1SS

Hydrogen Cyanide 0-30.0ppm

S3KU1SS

Fluorine 4ppm

S3KE1SS

Ethylene Oxide (ETO), 25.0ppm (20.0 to 50.0ppm)

Spares (Miscellaneous)

 

S3KDM

Replacement display module

S3KTM

Replacement terminal module

S3KDM3

Mk III Replacement display module

S3KTM3

Mk III Replacement terminal module

S3KTMTS

Terminal screw and 'U' clamp (bag of 20)

S3KWP

Weatherproof housing with bump test port for use with Series 3000 and XNX EC toxic sensors

SPXCDMAG

Magnet

SPXCDHWES

Hex wrench for earth screw

SPXCDEBS

Earth bracket and screws

S3KM20P

M20 Blanking Plug

S3KNPTP

3/4"NPT Blanking Plug


Service Online
Phone online