Honeywell Gas Detector About:

Midas gas detector | Sensepoint XCD | FSX Flame Detector | FS10-R FSX Flame Detectors | FS24X Flame Detector | Fire Sentry FS20X | Impulse portable gas detector | Satellite XT | SS4/SS2 Flame Detector | FS7 Flame Detector | HONEYWELL ANALYTICS PORTABLES |


Honeywell Gas Detector

Date:2017-10-20     Hits:2421

FSL100 Flame Detectors


Overview
The Honeywell Analytics FSL100 series of Flame Detectors comprises threemodels:
 FSL100-IR3 Triple Infrared flame detector
 FSL100-UV Ultraviolet flame detector
 FSL100-UVIR Ultraviolet and Infrared flame detector

Honeywell’s FSL100 range of Light Industrial/Commercial Flame Detectors enables simple coverage of fire hazard areas across many fire hazard applications. Installation, set-up and operation are simple. Wide solid area coverage and fast speed of response omtimize safety. With inbuilt automatic test and test lamps available to cover all models, reliability is ensured.
Features & Benefits
UV, UV/IR and IR3 Flame Detectors to cover a wide range of applications
Robust, simple to install & set-up; Wide angle and fast speed of response
Automatic test and test lamps for simple check and maintenance.
Quick Specs
FSL100 Flame Detectors - UV, UV/IR and IR3 for light industrial applications
GRP Housing, available in Red or White with optional swivel mount
12-14Vdc, 25mA nominal operation

4 to 20mA and Relay outputs.


Product Overview


The newest Optoelectronic flame detector for a wide range of Light Industrial fire detection from Honeywell Analytics.

A range of middle market Optical Flame Detectors joining the HA FSX High End products. Addresses a wide range of fire protection applications both indoors and outdoors. With 3 versions to cover a wide range of flaming fires: Ultraviolet (UV), Ultraviolet/Infrared (UV/IR) and Triple Infrared (IR3).

Detects wide range of Hydrocarbon & Non-Hydrocarbon fires
Detecting a wide range of Hydrocarbon and Non-Hydrocarbon flaming fires means that many application areas can be addressed.

Wide viewing angle
Optical detection of radiant energy in a solid angle Field of View enables coverage of a large risk area. Simple optional mounting bracket allows the FSL100 to be installed and aligned covering the hazard.

Fast response
Far faster than other technologies, by responding to flaming fires in seconds enabling a more rapid response to danger before the fire can escalate.

FM Class1, 2 & 3 Div2
Can be installed indoors or outdoors and in Hazardous areas typically looking into a Div 1 area from a distance.

FM 3260 performance cert
Certified to FM 3260 for flame Detector performance.

Relay and current output (Fault and Alarm)
Analog stepped output and Alarm/Fault relays for simple connectivity.

Inbuilt  Automatic Test and Simple to use Test Lamps 
FSL100 maintains continuous internal health monitoring. Test lamps enable simple operational and Field of View testing.


ACCESSORIES

FSL100 Swivel Mount
FSL100 - SM21
Allows the FSL100 to be installed and aligned covering the hazard.

FSL100 Test Lamp
FSL100 - TL
Covers the total FSL100 range, enabling fast checking of operational capability (included with Universal Charger and Carrying Case).


FSL100 Series Flame Detectors
UV, UV/IR, IR3
The FSL100 Series of flame detectors from Honeywell delivers robust, fast, and
reliable detection of flaming fires in a wide range of applications.
The range consists of UV, UV/IR and IR3 flame detectors.
All utilize sophisticated sensing and signal analysis to
detect fires quickly while also rejecting false alarms.
The FSL100 may be small and lightweight for
easy installation but it is designed to work in
tough indoor/outdoor environments, as well
as potentially explosive atmospheres.
With a large field of view it can
detect a range of different types
of fire including hydrocarbon
and non-hydrocarbon sources.
Available in UV, UV/IR and 3IR we
have your application covered.
Suitable for Many Applications
• UV, UV/IR and IR3 available
• Hydrocarbon and non-hydrocarbon sources
• Use in potentially explosive atmospheres
• Indoor and outdoor operation
• High visibility red or discrete white models available
Great Performance
• Approved to EN54-10 and FM3260 flame
detector standards
• Comprehensive automatic self test
•Remote manual self test option
Fast & Reliable
• High speed sensors and microprocessor
• Sophisticated analysis algorithms
• Continuous health monitoring
• False alarm rejection
Reduced Life Cost
• Long life elements
• Pressure compensation to avoid contamination
• 2 year warranty
• Buy with confidence
Ease of Installation and Use
• Relay and mA outputs as standard
• Lightweight GRP housing
• Pre-formed knockouts
• Optional swivel mounting bracket
• Long range test lamp available

FSL100-UV

• Suitable for indoor applications; for
example fume hoods and hydrogen
storage areas
• Effective solution for materials burning
with low temperatures, e.g. Sulphur
• Alarms to fires from heavy hydrocarbons (wood,
paper, petroleum, etc.), light hydrocarbons
(methanol, methane, etc.), and hydrogen
• Good resistance against the
influences of:
- Direct and reflected sunlight
- Artificial light, such as fluorescent
tubes and glass covered halogen lamps


FSL100-UV/IR

• Analysis of the flame flicker-frequency
for improved false alarm rejection
• Dual sensing methodology enables
a wide range of hydrocarbon and
non-hydrocarbon fires to be
effectively detected
• Good resistance against the influences of:
- Direct and reflected sunlight
- Artificial light, such as fluorescent tubes
and glass covered halogen lamps
- Arcs and electric discharges (static
or from e.g. electric motors)
- The radiation from electric welding
provided that the electric welding takes
place at a distance more than 10 feet from
the flame detector (a welding rod
contains organic compounds which
may produce a small flame)


FSL100-IR3

• Analysis of the flame flicker frequency
for improved false alarm rejection
• Particularly suited to liquid
hydrocarbon and dirty fires
• Affected less by window
contamination or smoky fires
• Good resistance against the
influences of:
- Direct and reflected sunlight
- Artificial light, such as fluorescent
tubes and glass covered halogen
lamps
- Arcs and electric discharges (static
or from e.g. electric motors)
- The radiation from electric welding
provided that the electric welding
takes place at a distance more
than 10 feet from the flame
detector (a welding rod contains
organic compounds which may produce a small flame)
• Especially suitable fires that emit
large amounts of smoke

GENERAL SPECIFICATION

SPECIFICATIONS: FSL100 SERIES FLAME DETECTORS
FSL100 Flame Detector types FSL100-UV, FSL100-UVIR and FSL100-IR3; Choice of red or white housings
Range 110 ft /35 m (IR3), 25 m/80 ft (UV, UV/IR) alarming within 10 seconds to a 1 ft2(0.1 m2
)n-heptane fire
Cone of vision 90˚minimum horizontal and vertical
Power 10-28 VDC (12-24 VDC nominal)
Local LEDs
Continuous green: normal operation
Continuous yellow: fault
Flashing yellow: Fault and guide to repeat self-test after a self-test failure
Continuous red: alarm
Current output
Standard available 4–20 mA (stepped, sinking, non-isolated)
• 0 mA power fault / microprocessor fault
• 2 mA optical fault
• 4 mA normal operation
• >20 mA alarm
Relay output:
- Alarm relay
- Fault relay
De-energized during normal operation, no alarm, SPDT, 30 VDC – 2 A, 60 W max. Energised during normal operation, no fault,
SPDT, 30 VDC – 2 A, 60 W max.
Cable gland & terminals Cable entry M20 clearance. Supplied with gland suitable for cable diameter from 0.2” (5.5mm) to 0.5”(13mm). Terminals
suitable for 0.5mm2 (20AWG) to 1.5mm2 (15AWG) wire
Start up times <10 sec
Alarm response time 8 to 30 sec
Alarm output settings Selectable LEDs and relays latching/non-latching; factory setting: latching
Automatic & manual Self-Test Automatic Sensor Test (built in Self-Test) and manual Self-Test
Operating current normal 25 mA at 24 VDC
Current in alarm, at 24 VDC ±75 mA at 24 VDC
Connections to:
• Fire control panels using end of line (EOL) and alarm resistors (current increase)
• Devices that operate via relay switched outputs
• PLCs with 4–20 mA inputs
End of line and alarm resistor
To be adjusted to the fire control panel; free terminals are dedicated to the resistors
Note: the alarm and EOL resistor must be rated 2 W min. each and the total power dissipation of both alarm and EOL resistor
should not exceed 2 W
Housing Glass Reinforced Polyester (GRP), Non-incendive. UV resistant, Self-Extinguishing V–0 (UL-94)
Swivel Mount PA66, UV resistant; Stainless Steel fixings; 280 g (0.62 lb)
Pressure compensating element PCE (Pressure Compensating Element) avoids moisture build-up in the detector housing due to changes in ambient air-pressure
Dimensions 4.9 x 3.15 x 2.25 in (125 x 80 x 57 mm)
Weight 1.05 lb (465 g)
Ingress protection IP65
Temperature, operating –40 ˚F to +158 ˚F (–40 ˚C to +70 ˚C)
Temperature, ambient ATEX and FM class 3611 –13 ˚F to +158 ˚F (–25 ˚C to +70 ˚C)


Ordering Information

Part Number Description
FSL100-UV
UV flame detector suitable for:
 ATEX Zone 2/22
 FM 3611 Class 1, 2 and 3, Div 2
 EN54-10 certificate
 FM3260 approval
FSL100-UV-W Same specification as UV; white body
FSL100-UVIR
UVIR flame detector suitable for
 ATEX zone 2/22
 FM3611 Class 1, 2 and 3, Div 2
 EN54-10 certificate
 FM3260 approval
FSL100-UVIR-W Same specification as UVIR; white body
FSL100-IR3
Triple IR flame detector suitable for:
 ATEX zone 2/22
 FM3611 Class 1, 2 and 3, Div 2
 EN54-10 certificate
 FM3260 approval
FSL100-IR3-W Same specification as IR3; white body
FSL100-SM21 Swivel mount (Optional)
FSL100-TL FSL100 test lamp, incl. universal charger and carrying case; safe areasonly