Date:2017-10-20 Hits:6257
Industrial Gas Systems
Sensepoint XCL is a fixed gas detector that delivers the safety and compliance you expect — plus the affordability and ease of use that you don’t. It was designed especially for commercial and light industrial applications, delivering just the right amount of functionality to protect people on your premises and ensure compliance with regulations. Sensepoint XCL combines a simple yet robust mechanical housing with a gas detector app, so you can use everyday technology to set up and maintain your gas detector — and quickly get back to business. Sensepoint XCL is available as a flammable gas detector for the detection of potentially explosive gases, or as a toxic gas detector for the detection of a range of toxic gas hazards commonly found in commercial premises.
Features & Benefits
Manage installation, commissioning and maintenance from the gas detector app on your smartphone
Aesthetic design blends in to the environment
Simple, robust housing with our easiest ever installation and maintenance
Integral gassing port for hard-to-reach locations
Compatible with Touchpoint Plus and other industry-standard controllers
Quick Specs
mA loop or Modbus RTU output with optional relays
Multi-colour LED status indicator
Operating temperature −20 to 50°C, ingress protection IP65
Choice of toxic, oxygen or flammable sensors
Product Overview
Thanks to Honeywell’s use of Bluetooth Low Energy (BLE) technology, you can install, commission and maintain your Sensepoint XCL gas detector — all from the palm of your hand. Simply pair the detector with your smartphone; then use Honeywell’s Sensepoint XCL gas detector app to wirelessly perform many tasks — from adjusting set points to checking fault codes — from up to 10 meters away.
Everything you need for installation is in the box, organized for fast, convenient startup. Use our simple drilling templates and a standard toolkit for installation. And for initial calibration, all you need is our gas detector app on your smartphone and a cylinder of calibration gas — no need for walkie-talkie guidance with the control room. Use the app to create a profile for the detector, choose alarm set points, run test procedures and automatically generate a commissioning report, which you can send from your phone to other stakeholders or store for easy access in a safety inspection. No need for paperwork.
Sensepoint XCL's smartphone-based experience significantly reduces the time you spend on gas detector maintenance. For sensor replacement, simply remove one screw on the cover plate, and our app guides you on the rest. And when doing maintenance checks, our app puts diagnostic information at your fingertips.
You can also save valuable time with easy reporting on the smartphone app. Whether you need a maintenance report for a certain detector or a gas history for a safety audit, just select the right report on the app and send it to other parties — or store it for easy recall.
For a complete gas leak detection system, Sensepoint XCL has the perfect partner in Touchpoint Plus, a configurable, easy-to-use controller for up to sixteen channels of gas detection.
Accessories
Part number Description
SPXCLCAL Sensepoint XCL Calibration/Flow Cap
SPXCLDMK Sensepoint XCL Duct Mount Kit
SPXCLRGP Sensepoint Fixed Remote Gassing Port
SPXCLGLD Sensepoint XCL M20 Cable Glands (10 pieces each pack)
Detectable Gases
Sensepoint XCL is available for the detection of the following gases:
• Oxygen (O2)
• Toxic gases
– Ammonia (NH3)
– Carbon monoxide (CO)
– Hydrogen (H2)
– Hydrogen sulfide (H2S)
– Nitrogen dioxide (NO2)
• Combustible gases
– Methane (CH4)
For additional combustible gas availability, contact Honeywell
Analytics.
Ordering Information
C.1 Detectors
Part number Description
SPLLO1XAXCXNZZ Sensepoint XCL Transmitter, Compliance, Safe Area, IP65, O2, 4–20 mA, Charcoal
SPLLF6XAXCXNZZ Sensepoint XCL Transmitter, Compliance, Safe Area, IP65, CH4 (CAT), 4–20 mA, Charcoal
SPLLC1XAXCXNZZ Sensepoint XCL Transmitter, Compliance, Safe Area, IP65, CO (L), 4–20 mA, Charcoal
SPLLC2XAXCXNZZ Sensepoint XCL Transmitter, Compliance, Safe Area, IP65, CO (H), 4–20 mA, Charcoal
SPLLH1XAXCXNZZ Sensepoint XCL Transmitter, Compliance, Safe Area, IP65, H2S (L), 4–20 mA, Charcoal
SPLLH2XAXCXNZZ Sensepoint XCL Transmitter, Compliance, Safe Area, IP65, H2S (H), 4–20 mA, Charcoal
SPLLG1XAXCXNZZ Sensepoint XCL Transmitter, Compliance, Safe Area, IP65, H2, 4–20 mA, Charcoal
SPLLN1XAXCXNZZ Sensepoint XCL Transmitter, Compliance, Safe Area, IP65, NO2, 4–20 mA, Charcoal
SPLLA1XAXCXNZZ Sensepoint XCL Transmitter, Compliance, Safe Area, IP65, NH3 (L), 4–20 mA, Charcoal
SPLLO1XAXWXNZZ Sensepoint XCL Transmitter, Compliance, Safe Area, IP65, O2, 4–20 mA, White
SPLLF6XAXWXNZZ Sensepoint XCL Transmitter, Compliance, Safe Area, IP65, CH4 (CAT), 4–20 mA, White
SPLLC1XAXWXNZZ Sensepoint XCL Transmitter, Compliance, Safe Area, IP65, CO (L), 4–20 mA, White
SPLLC2XAXWXNZZ Sensepoint XCL Transmitter, Compliance, Safe Area, IP65, CO (H), 4–20 mA, White
SPLLH1XAXWXNZZ Sensepoint XCL Transmitter, Compliance, Safe Area, IP65, H2S (L), 4–20 mA, White
SPLLH2XAXWXNZZ Sensepoint XCL Transmitter, Compliance, Safe Area, IP65, H2S (H), 4–20 mA, White
SPLLG1XAXWXNZZ Sensepoint XCL Transmitter, Compliance, Safe Area, IP65, H2, 4–20 mA, White
SPLLN1XAXWXNZZ Sensepoint XCL Transmitter, Compliance, Safe Area, IP65, NO2, 4–20 mA, White
SPLLA1XAXWXNZZ Sensepoint XCL Transmitter, Compliance, Safe Area, IP65, NH3 (L), 4–20 mA, White
SPLCO1BAXCXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, O2, 4–20 mA, Charcoal
SPLCO1BARCXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, O2, 4–20 mA, Relay, Charcoal
SPLCO1BAXWXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, O2, 4–20 mA, White
SPLCO1BARWXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, O2, 4–20 mA, Relay, White
SPLCO1BMXCXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, O2, Modbus, Charcoal
SPLCO1BMRCXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, O2, Modbus, Relay, Charcoal
SPLCO1BMXWXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, O2, Modbus, White
SPLCO1BMRWXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, O2, Modbus, Relay, White
SPLCC1BAXCXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, CO, 4–20 mA, Charcoal
SPLCC1BARCXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, CO, 4–20 mA, Relay, Charcoal
SPLCC1BAXWXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, CO, 4–20 mA, White
SPLCC1BARWXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, CO, 4–20 mA, Relay, White
SPLCC1BMXCXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, CO, Modbus, Charcoal
SPLCC1BMRCXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, CO, Modbus, Relay, Charcoal
SPLCC1BMXWXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, CO, Modbus, White
SPLCC1BMRWXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, CO, Modbus, Relay, White
SPLCH1BAXCXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, H2S (L), 4–20 mA, Charcoal
SPLCH1BARCXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, H2S (L), 4–20 mA, Relay, Charcoal
SPLCH1BAXWXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, H2S (L), 4–20 mA, White
SPLCH1BARWXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, H2S (L), 4–20 mA, Relay, White
SPLCH1BMXCXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, H2S (L), Modbus, Charcoal
SPLCH1BMRCXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, H2S (L), Modbus, Relay, Charcoal
SPLCH1BMXWXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, H2S (L), Modbus, White
SPLCH1BMRWXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, H2S (L), Modbus, Relay, White
SPLCH2BAXCXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, H2S (H), 4–20 mA, Charcoal
SPLCH2BARCXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, H2S (H), 4–20 mA, Relay, Charcoal
SPLCH2BAXWXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, H2S (H), 4–20 mA, White
SPLCH2BARWXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, H2S (H), 4–20 mA, Relay, White
SPLCH2BMXCXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, H2S (H), Modbus, Charcoal
SPLCH2BMRCXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, H2S (H), Modbus, Relay, Charcoal
SPLCH2BMXWXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, H2S (H), Modbus, White
SPLCH2BMRWXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, H2S (H), Modbus, Relay, White
SPLCG1BAXCXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, H2, 4–20 mA, Charcoal
SPLCG1BARCXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, H2, 4–20 mA, Relay, Charcoal
SPLCG1BAXWXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, H2, 4–20 mA, White
SPLCG1BARWXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, H2, 4–20 mA, Relay, White
SPLCG1BMXCXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, H2, Modbus, Charcoal
SPLCG1BMRCXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, H2, Modbus, Relay, Charcoal
SPLCG1BMXWXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, H2, Modbus, White
SPLCG1BMRWXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, H2, Modbus, Relay, White
SPLCN1BAXCXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, NO2, 4–20 mA, Charcoal
SPLCN1BARCXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, NO2, 4–20 mA, Relay, Charcoal
SPLCN1BAXWXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, NO2, 4–20 mA, White
SPLCN1BARWXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, NO2, 4–20 mA, Relay, White
SPLCN1BMXCXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, NO2, Modbus, Charcoal
SPLCN1BMRCXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, NO2, Modbus, Relay, Charcoal
SPLCN1BMXWXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, NO2, Modbus, White
SPLCN1BMRWXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, NO2, Modbus, Relay, White
SPLCA1BAXCXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, NH3 (L), 4–20 mA, Charcoal
SPLCA1BARCXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, NH3 (L), 4–20 mA, Relay, Charcoal
SPLCA1BAXWXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, NH3 (L), 4–20 mA, White
SPLCA1BARWXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, NH3 (L), 4–20 mA, Relay, White
SPLCA1BMXCXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, NH3 (L), Modbus, Charcoal
SPLCA1BMRCXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, NH3 (L), Modbus, Relay, Charcoal
SPLCA1BMXWXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, NH3 (L), Modbus, White
SPLCA1BMRWXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, NH3 (L), Modbus, Relay, White
SPLCF6BAXCXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, CH4 (CAT), 4–20 mA, Charcoal
SPLCF6BARCXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, CH4 (CAT), 4–20 mA, Relay, Charcoal
SPLCF6BAXWXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, CH4 (CAT), 4–20 mA, White
SPLCF6BARWXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, CH4 (CAT), 4–20 mA, Relay, White
SPLCF6BMXCXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, CH4 (CAT), Modbus, Charcoal
SPLCF6BMRCXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, CH4 (CAT), Modbus, Relay, Charcoal
SPLCF6BMXWXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, CH4 (CAT), Modbus, White
SPLCF6BMRWXNZZ Sensepoint XCL Transmitter, Safe Area, IP65, CH4 (CAT), Modbus, Relay, White
SPLCC1BAXCXLZZ Sensepoint XCL Transmitter, Safe Area, IP65, CO, 4–20 mA, Charcoal, CoLA
SPLCC1BARCXLZZ Sensepoint XCL Transmitter, Safe Area, IP65, CO, 4–20 mA, Relay, Charcoal, CoLA
C.2 Accessories
Part number Description
SPXCLCAL Sensepoint XCL Calibration/Flow Cap
SPXCLDMK Sensepoint XCL Duct Mount Kit
SPXCLRGP Sensepoint Fixed Remote Gassing Port
SPXCLGLD Sensepoint XCL M20 Cable Glands (10 pieces each pack)
C.3 Consumables
Part number Description
SPXCLZZO1SS Sensepoint XCL Replacement Sensor, O2
SPXCLZZF6SS Sensepoint XCL Replacement Sensor, Flam CAT
SPXCLRLC1SS Sensepoint XCL/XRL Replacement Sensor, CO
SPXCLRLH1SS Sensepoint XCL/XRL Replacement Sensor, H2S (suitable for both Low and High Range)
SPXCLRLG1SS Sensepoint XCL/XRL Replacement Sensor, H2
SPXCLRLN1SS Sensepoint XCL/XRL Replacement Sensor, NO2
SPXCLRLA1SS Sensepoint XCL Replacement Sensor, NH3
SPXCLFLT Sensepoint XCL Replacement Sensor Filter (10 pieces each pack)
C.4 Spares
Part number Description
SPXCLSK1 Sensepoint XCL Service Kit
SPXCLSCC Sensepoint XCL Sensor Cover, Charcoal
SPXCLSCW Sensepoint XCL Sensor Cover, White
SPXCLDCC Sensepoint XCL Decal Cover, Charcoal
SPXCLDCW Sensepoint XCL Decal Cover, White